Models ST51 and ST51A are a compact, low cost solution for accurate, repeatable flow measurement of biogas, digester gas, landfill gas, methane and natural gas as well as air, compressed air or nitrogen. This insertion-style flow meter has no moving parts and is available in probe lengths for installation into pipe diameters from 2.5 inches to 24 inches [63 mm to 610 mm]. It is easily connected into the pipe via a 1/2 inch or 3/4 inch NPT compression fitting. ST51 uses constant power thermal dispersion drive technology, with a slightly heated sensor, which uniquely provides a subtle drying effect on the sensors that results in effective measurement in moist gas applications. The ST51 Series electronics are housed in rugged, IP67 rated enclosure with dual conduit ports in either NPT or M20 threading. The instrument comes standard with dual 4-20 mA, NAMUR NE43 complaint outputs and a 500 Hz pulse output. The model ST51A adds HARTor Modbus,a higher process temperature service range, a SIL compliance rating and extended warranty. The transmitter/electronics can be integrally mounted with the flow element (probe) or be remote mounted to best match your installation situation. The complete instrument carries global Ex agency approvals for Division l/Zone 1 installations. The ST51 flow sensing element features precision, platinum RTD in small diameter, "equal-mass," all-metal thermowells to provide superior accuracy, repeatability and fast response.
Class I, Division 1, Groups B, C, D; T4 Ta = +60°C; Type 4X, IP66 Class II/III, Division 1, Groups E, F, G; T4 Ta = +60°C; Type 4X, IP66 Model ST51 also includes: Nonincendive for Class I, Division 2, Groups A, B, C, D; T4 Ta = +60°C; Type 4X, IP66
ATEX:
Zone 1, Zone 21 II 2 G Ex db IIC T6...T1 Gb II 2 D Ex tb IIIC T85°C... T300°C Db; IP66/IP67 Ta = -40°C to +65°C
IECEx:
(EQM/ECAS)
Ex db IIC T6...T1 Gb; Ex tb IIIC T85°C...T300°C Db; IP66/IP67 Ta=-40°C to +65°C
Other:
EAC (TRCU) Russia, Kazakh MPA (Kazakhstan), NEPSI, CE Marking, CRN
SIL (ST51A):
SIL 1 compliant; Safe Failure Fraction (SFF) 78.5% to 81.1%
Pipe/Line Size Compatibility: 2 1/2" to 24" [64 mm to 610 mm]
Flow Rate: 0.3 SFPS to 400 SFPS [0,08 MPS to 122 MPS]
Accuracy: (at calibrated conditions)
Standard: ± 2% reading, ± 0.5% full scale
Optional: ± 1% reading, ± 0.5% full scale
Temperature Coefficient: (at calibrated conditions) With optional extended temperature compensation; valid from 10% to 100% of full-scale calibration
Flow: Maximum ± 0.015% of reading/ºF up to 350ºF [±0.03% of reading/ºC up to 177ºC]
Repeatability: ± 0.5% reading
Temperature Compensation:
Standard: 40°F to 100°F [4°C to 38°C];
Optional: 0°F to 350°F [-18°C to 177°C]
Turndown Ratio: 3:1 to 100:1
Warranty: ST51: 1 year ST51A: 2 years
Flow Element
Installation: Insertion
Type: Thermal dispersion
Material of Construction: 316 stainless steel body with Hastelloy-C thermowell sensors, 316 stainless steel compression fitting with teflon or stainless steel ferrule, optional 316 stainless steel packing gland.
Pressure (Maximum Operating without Damage):
Stainless steel ferrule: 500 psig [34 bar(g)]
Teflon ferrule: 150 psig [10 bar(g)]
Packing gland: 500 psig [34 bar(g)]
Operating Temperature:
Stainless steel ferrule
ST51: 0°F to 250°F [-18°C to 121°C] ST51A: 0°F to 350°F [-18°C to 177°C]
Teflon ferrule: 0°F to 200°F [-18°C to 93°C]
Process Connection: Compression Fittings: 1/2 ″ MNPT or 3/4 ″ MNPT with stainless steel or Teflon ferrule Retractable Packing Gland: Medium pressure 500 psig [34 bar(g)] with 1/2 ″ MNPT or 3/4 ″ MNPT, and either graphite or Teflon packing Teflon packing is required if media is ozone, chlorine, or bromine
Insertion Length (Field Adjustable):
1" to 6" [25 mm to 152 mm]
1" to 12" [25 mm to 305 mm]
1" to 18" [25 mm to 457 mm]
Flow Transmitter
Enclosure: Rating: NEMA 4X, IP66/IP67 Material: Standard – Polyester powdered coated, ≤0.4% CU, low/no copper content*2 aluminum (*2: Standard effective April 2023) Optional – 316 stainless steel Conduit/Cable Port: Dual 1/2″ NPT or M20x1.5
Operating Temperature: 0°F to 140°F [-18°C to 60°C]
Input Power: DC: 18 Vdc to 36 Vdc (6 watts max.) AC: 85 Vac to 265 Vac (12 watts max.; CE Marking approval from 100 Vac to 240 Vac)
Analog Output Signals: Dual 4-20 mA, user assignable to flow rate and/or temperature and a 0-500 Hz pulse output for total flow; output #1 has fault indication per NAMUR NE43 guidelines, user selectable for high (> 21.0 mA) or low (< 3.6 mA)
Bus Communications (ST51A): HART: Version 7. FieldComm Group certified; available over output #1; DD file included. Modbus: RS485 (RTU and ASCII). Standard MS (16 bit), Standard LS (16 bit) and Daniel extension (32 bit).
Communication Port: RS-232C
Digital Display (Optional): Two-line x 16 character LCD; displays measured value and engineering units; top line assigned to flow rate, second line user assignable to temperature reading, as flow totalizer or alternating; display can be rotated in 90° increments for optimum viewing orientation
Installation and Mounting: Integral with sensor element or remote mountable up to 50′ [15 m] with Model ST51, and up to 100′ [30 m] with Model ST51A
Downloadable Documents
Quick Access
No uploaded documents found.
check_circleProduct added to cart
This website uses cookies to improve your experience. By continuing to use our site, you agree to our cookie policy.
cookie
Cookie Policy
The categories of cookies we use on this website are listed below. Mandatory cookies are essential for site functionality and cannot be disabled.
lock
Mandatory Cookies
Always Active
These cookies are essential for the proper functioning of the website and cannot be disabled. They are typically used to provide services such as setting your privacy preferences, logging in, or filling out forms.
analytics
Analytical Cookies
These cookies help us understand how visitors interact with the website. This information is used to improve the user experience.
ads_click
Marketing Cookies
These cookies are used to show you personalized advertisements based on your interests.