The FLT93F insertion type FlexSwitch for flow and temperature monitoring represents the first true technological breakthrough in thermal technology in over a decade. This product was designed for heavy industrial environments including high temperature and high pressure. FCI is the only thermal manufacturer providing temperature compensation to ensure set point accuracy for process temperatures that vary up to ±100°F.
The FLT93F offers fast response time and is suitable for small process connections. This product is easily field-configured or factory preset, providing unparalleled flexibility, accuracy and stability for all multiple process sensing and switching requirements.
0.25 to 120 sfps [0.08 to 37 smps] at standard conditions of 70° F [21.1° C] and 14.7 psia [1.013 bar(g)].
Accuracy: (whichever reading is higher) Liquids: ± 0.5% reading or ± 0.04 fps [± 0.012 mps] Gases: ± 0.5% reading or ± 2 sfps [± 0.06 nmps]
For Temperature Service:
Accuracy: ± 2° F [±1° C]
Repeatability: ± 1° F [± 0.6° C]
Response Time: As low as 0.5 seconds.
Enclosure: NEMA 4X/IP66 Rated. Standard: Polyester power coated aluminum, with single 1" NPT conduit port. Optional: Stainless steel. Optional: Dual-conduit port, aluminum with 1/2" NPT or M20 metric conduit ports.
Compliances and Agency Approvals: FM, FMc, ATEX, IECEx, EAC/TR CU, Inmetro, EQM/ECAS. CE mark. PED, CRN. (UKCA, UKEX pending) Meets EC directives for EMC and LVD. Probe complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device.
FM/FMc:
XP, Class 1, Div. 1 Groups B,C,D, T3A or T4 Ta ≤60°C DIP, Class II/III, Div. 1, Groups E,F,G, T3A or T4 Ta ≤60°C Nonincendive for Class I, II and III, Division 2, Groups A,B,C,D,E,F, and G, T3A or T4 -40°C ≤Ta≤60°C; hazardous (classified) locations, indoors and outdoors. Type 4X
ATEX:
Integral: II 2 G Ex db IIC T4…T2 Gb II 2 D Ex tb IIIC T135°C…T300°C Db Remote enclosure + electronics: II 2 G Ex db IIC T6 Gb II 2 D Ex tb IIIC T85°C Db Local enclosure + sensor II 2 G Ex db IIC T4…T1 Gb II 2 D Ex tb IIIC T135°C…T345°C Db
Pigtail version II 2 G Ex db IIC T4…T3 Gb II 2 D Ex tb IIIC T135°C…T200°C Db
IECEx: (EQM/ECAS)
Integral: Ex db IIC T4…T2 Gb Ex tb IIIC T135°C…T300°C Db Remote enclosure + electronics: Ex db IIC T6 Gb Ex tb IIIC T85°C Db Local enclosure + sensor Ex db IIC T4…T1 Gb Ex tb IIIC T135°C…T345°C Db
Pigtail version Ex db IIC T4…T3 Gb Ex tb IIIC T135°C…T200°C Db
Optional N.I.S.T. Flow Calibration Services Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above.
Flow Element
Materials of Construction: All welded 316L stainless steel for all wetted surfaces.
Process Connection: 0.75 inch male NPT
Insertion Length:
1.2 inch [30 mm]
2 inches [51 mm]
4 inches [102 mm]
6 inches [152 mm]
9 inches [229 mm]
12 inches [305 mm]
18 inches [457 mm]
Customer specified lengths are available as an option.
Operating Temperature:
Standard: -40° to +350° F [-40° to +177° C]
Optional: -100° to +500° F [-73° to +260° C]
Operating Pressure: To 3500 psig [240 bar(g)]
Control Circuit
Operating Temperature: -40° to +140° F [-40° to +60° C]
Universal AC/DC supply. Input terminals and jumpers on circut board select specific power.
AC
108-132V
13W, 100mA max.
AC
207-253V*
14W, 50mA max.
AC
18-28V
7W, 230mA max.
DC
21-30V
7W, 230mA max.
* AC mains preset by factory: FM & FMc as 108-132 Vac; All others as 207-240 Vac
Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or 24 Vdc.
Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.
Electrical Connection: 1 inch female NPT
Remote Configuration: Available as an option with customer specified interconnecting cable length.
Downloadable Documents
Quick Access
No uploaded documents found.
check_circleProduct added to cart
This website uses cookies to improve your experience. By continuing to use our site, you agree to our cookie policy.
cookie
Cookie Policy
The categories of cookies we use on this website are listed below. Mandatory cookies are essential for site functionality and cannot be disabled.
lock
Mandatory Cookies
Always Active
These cookies are essential for the proper functioning of the website and cannot be disabled. They are typically used to provide services such as setting your privacy preferences, logging in, or filling out forms.
analytics
Analytical Cookies
These cookies help us understand how visitors interact with the website. This information is used to improve the user experience.
ads_click
Marketing Cookies
These cookies are used to show you personalized advertisements based on your interests.